Installation Instructions for. 30-4110. Gauge-Type UEGO Controller. Figure 4. Gauge Side Harness Connections. RED <Power> Connect to a switched 10-18 volt power source utilizing a 10A fuse. BLACK <Ground> Connect to a clean power ground. Table 1. Lambda input channel locations for AEM EMS.
12 Aug 2014
There are four flying leads from the AEM UEGO Gauge. Connection for two of the wires is mandatory and optional for the other two, as shown below. RED <Power> Connect to a switched 10-18 volt power source utilizing a 10A fuse. BLACK <Ground> Connect to a clean power ground.
User Instructions for the AEM 30-4350 TRU-Boost · Ford Muscle Magazine - Wideband AFR Shoot-Out Results, including the AEM & Innovate. Ok, it's not an instruction manual but you might find this interesting. Ford Muscle Magazine conducted a shoot out of all the most popular AFR Wideband Kits. See their results here,
2004 Advanced Engine Management, Inc. Page 1. Installation Instructions for. 30-4113, 30-4123, 30-4213, 30-4223. WARNING: 0-5V AFR Gauge !uncomfortable with anything about this, please refer the installation to an AEM trained tuning shop or call 800-423-0046 for technical assistance. You should also visit the AEM.
Analog Wideband Air/Fuel Ratio Gauge. Figure 1. Wiring Schematic. AEM Gauge-Type UEGO Controller Parts. 1 x 35-5130(B/W) UEGO Gauge Assembly. 1 x 30-2001 UEGO Sensor. 1 x 35-8535 Install Kit (O2 Bung with 6 Butt Connectors). 1 x 10-5130 Installation Instructions. 1 x 35-3411 8-Pin Power Harness. 1 x 35-3400

DAMAGE THAT RESULTS FROM THE MISUSE OF THIS PRODUCT. Instruction. Manual. The 52mm (2-1/16”) AEM X-Series Universal Exhaust Gas Oxygen (UEGO) Gauge features a four digit central readout and sweeping 24-color-coded LED display, providing immediate reference to the engine air fuel ratio (or lambda)
Diagram from AEM RED (Power) - Connect to a switched 10-18 volt power source utilizing a 10A fuse. BLACK (Ground) - Connect to a clean power ground. WHITE (Analog Output) - Connects to any Stand Alone ECU unit that accepts a 0-5 volt input. BLUE (Serial Output)(optional hookup) - Connects to a RS-232 com port